2845539
ELETTRONICA PAGANI OPERA INFINITY
Beyond the usual electrotherapy device
2849162
Draining electrotherapy
Use of this particular exponential waveform helps to improve circulation, accelerates and facilitates venous return, attenuates problems and pain coming from swelling and edema.
IF waveforms from 2 to 20 KHz
IF waveforms could be adjusted both in intensity (vertically) and also into the carrier frequency (horizontally). In this latest opportunity, during treatment it is possible to apply to the patient different kind of frequencies provoking several effects, such as anti-inflammation and edema, stimulations of fibers and muscles, pain relief. This is why those kinds of waveforms could be useful for treating complex pathologies, where pain is associated to edema, or edema is associated to traumas, or pain is associated to muscle contraction and sprain.
Continuous and pulsed vacuum device (on inquiry)
Vacuum could be useful for performing specific treatments such as cheloidis, drainage, or to apply IF currents with the aim to be effective in provoking hyperemia effects.
Technical Features:
- Outputs: 2, independent into the choice of current and intensity
- Maximum intensity: 76.5 mA
- Low frequency: Galvanic and interrupted galvanic, diadynamic , rectangular, triangular, biphasic, exponential, Trabert, faradics, drainage
- Medium frequency: from 2 to 20 KHz, Bipolar and quadripolar, IF isoplanar, IF vectorial, MF stimulation, Kotz, IF isodynamic.
- High voltage: on inquiry
- Continuous and pulsed vacuum: on inquiry
- Display: 480x800 pixels: colored touch-screen
- Pre-set programs with body pictures
- Free Memories
- Therapeutic objectives
2845542
ELETTRONICA PAGANI HC UNISTIM
The universal electrotherapy device
2849163
Mid horizontal frequency currents
Horizontal IF currents are special IF currents for which the operator, further to the intensity, may adjust frequency by keeping intensity stable or by also setting intensity. Usually IF Horizontal currents are suitable for treating pain and inflammation. Usually, it is a very comfortable current that the patient feels very well all over the body.
Electrical stimulation
Contraction of muscles could be performed by stimulating the muscle itself or the nervous fibers. While denervated muscles are present, it is necessary to stimulate muscles for avoiding degeneration and athrophy of the muscles. The most useful waveforms are the rectangular, triangular and exponential pulses which can be adjusted up to 1000 msec, with reference to the denervation.
Stimulation of normal muscles
Contraction, without any denervated muscles is performed after non-used muscles, due to surgical intervention, amiothrophy, but also for improving force, endurance and the general performances of muscles. At this end, usually, it is suggested to use Biphasic, Kotz, faradic currents; it depends on the type of muscles, on the status of the muscles and also on the sensitivity of each patient. The most suitable current is the waveform capable to provoke the best stimulation, by respecting the patient’s comfort.
Veno-lymphatic current (drainage)
Veno-lymphatic current is a special exponential waveform, capable to improve blood circulation, accelerates venous flow, reduces pain coming from inflammation and edema.
Technical features
- Outputs: 2
- Waveforms: galvanic and interrupted galvanic, diadynamics (50-100 Hz, CP, LP, 50 & 100Hz interrupted), rectangular, triangular, exponential, biphasic, Trabert, faradics (neodyn, rectangular, triangular), IF Bipolar and quadripolar, isoplanar, vectorial, mf of stimulation, Kotz, If horizontal current, Drainage current
- Intensity: 76,5 mA (150 mAp)
- Display: coloured graphic with touch-screen
- Pre-set protocols with pictures
- Free memories for customized protocols
- Continuous and pulsed vacuum: on inquiry
- High voltage current: on inquiry
- Continuous and Pulsed Vacuum therapy: on inquiry
- Trolley with 4 boxes
2845541
ELETTRONICA PAGANI MASTER
The evolution is exciting!
2849164
Only one thing is left from the previous MASTER: the name. Everything else is new!
The new MASTER has all the prerogatives to recapture the successful performance and reliability of its founder. It comes with a large LCD colour display and innovative and user-friendly software that can deliver all the currents, a modern and aggressive design, and just the right size for any clinical setting, while being easy to transport. Everything is made with attention to the smallest detail to meet the most diverse operating needs in an efficient and functional manner.
MASTER is available in a version with one channel with low frequency currents and two channels with low and medium frequency currents.
Available versions:
Master 1
- 1 output channel
- Iontophoresis with galvanic and interrupted galvanic currents
- Tens and biphasic
- Diadynamic
- Rectangular and triangular
Master 2
- 2 output channels
- Iontophoresis with galvanic and interrupted galvanic currents
- Tens and biphasic
- Diadynamic
- Rectangular and triangular
- Interfere
2846697
ELETTRONICA PAGANI
TOWER 2-STIM & 4-STIM
Innovative, convienient, versatile
2849165
Tower 2 STIM
Capable to deliver all most useful low and mid frequency currents. Currents are delivered from 2 difefrent output channels where intensity could be adjusted separately, while a wide range of pre-set protocols with body pictures and memories are available for granting best versatility.
- With 2 outputs (4 electrodes)
- Tens & Biphasic
- Diadynamics
- Kotz
- Denervated muscle stimulations
- Crossover 4-pole & 2-pole application
- Galvanic
Tower 4 STIM
A modern device for performing stimulating normo-innervated muscles, pain relief, drainage, improvement of muscular performances.
- With 4 outputs (8 electrodes)
- TENS
- Biphasic
- Galvanic
Technical features for both TOWER 2 STIM & 4 STIM
Color screen with Greek menu
Illustration of a disease by body area
Ready treatment protocols
Empty memory slots
Battery (optional)
Carrying bag (optional)
CE certification
* With a simple movement any TOWER device changes unit and converts to any other device in the TOWER series: 2-channel electrotherapy (model 2STIM), 4-channel electrotherapy (model 4STIM), Ultrasound 1 & 3 MHz ( model SOUND), Magnetotherapy (model MAG), Laser (model LIGHT), Tecar (model TRC).
2846698
ELETTRONICA PAGANI STAR INFINITY
The star of the electrotherapy devices
2849166
Outputs: 2 completely independent (connection of 4 electrodes)
Active currents: Galvanic, Galvanic Switch, Dynamic (50 & 100 Hz, CP, LP, Two-phase, Single-phase), Pulsed (Triangle, Square, Trabert, Exponential), Phared (Triangle, Square, Neodynamic), TENS, Burst Modulated), Crossover (Bipolar, Quadrupole, Isoplanar, Classical), Kotz, MF Stimulation, Venous Lymphatic Stimulation (on request), High Voltage (on request), Frequency & Voltage Equivalents (on request)
Integrated vacuum suction (STAR Infinity Fix): on inquiry
Ready-made treatment protocols with display of electrode placement on the screen
Infinite memory positions
6.5 "color LCD touch screen
Proposed combination of treatments
Greek menu
CE certification
Wheeled STAR Slim or wheeled STAR (optional)
2849392
ELETTRONICA PAGANI X5EU
Combined ultrasound and electrotherapy device
2849393
R2 X5EU includes all special features belonging to the most modern therapeutic generators for electrotherapy and ultrasound therapy. X5EU is the most versatile combined device for electrotherapy and ultrasound. 1 & 3 MHz multifrequency ultrasound therapy is combined to the universal electrotherapy device, capable to perform every useful current alone or also combined to the ultrasound waves.
The universal electrotherapy generator is provided with two outputs. X5EU allows the operator to set every pathology whit all the widest range of parameters, over the Windows CE platform; also, the operator may use a lot of pre-set protocols with the relevant pictures, for placing correctly the relevant electrodes and/or ultrasound head.
Combination of the two available generators, ultrasound and electrotherapy, also grants more therapeutic benefits, due to the sum of the combined effects into the same time.
Technical features:
Ultrasound therapy
Frequency: 1-3 MHz
Emission: continuous and pulsed (from 20 to 80%)
Modulation: 1 to 200 Hz
5cm2 multifrequency head for single and combined use
Timer max. 30 min
Intensity max: 3 W cm2
Real-time attesting no-coupling between patient’s tissue and us head
Electrotherapy
Outputs: n. 2
Intensity max.: 76,5 mA
Low frequency: Galvanic, interrupted galvanic, diadynamics (50-100 Hz, CP, LP, 50 and 100 Hz interrupted), rectangular, exponential, triangular, Biphasic, Trabert, Faradics, drainage current.
Mid frequency: 2,0 KHz to 20 KHz
IF bipolar, IF quadripolar, IF isoplanar, IF vectorial, MF of stimulation, Kotz, IF horizontal
Graphic and colored LCD with touch-screen
Pre-set programs with body pictures
Free memories
Therapeutic objective
On inquiry:
HV current
Trolley with or without drawers
1 cm2 1-3 MHz head
1 MHz 8 cm large head with strap for static and underwater treatments
Connector combining electrotherapy to ultrasound therapy.
2849394
ELETTRONICA PAGANI HC SOUNDSTIM
The most versatile combined device for Electrotherapy & Ultrasound
2849395
HC SOUNDSTIM allows to select both single generator (ultrasound or electrotherapy) and also to combine the two generators for mixing ultrasound to electrotherapy. Mainly, the combination is made for performing pain relief and anti-inflammatory applications and it is generally more effective than the single technique both for reducing application time and granting better results.
Technical features
Ultrasound
Frequency: 1-3 MHz
Emission: continuous and pulsed (from 20 to 80%)
Modulation: 1 to 200 Hz
5cm2 multifrequency head for single and combined use
Ergonomic 1 - 3 MHz head for massage and under-water applications
Timer max. 30 min
Intensity max: 3 W cm2
Real-time attesting no-coupling between patient’s tissue and us head
Electrotherapy
Outputs: n. 2
Intensity max.: 76,5 mA
Low frequency: Galvanic, interrupted galvanic, diadynamics (50-100 Hz, CP, LP, 50 and
100 Hz interrupted), rectangular, exponential, triangular, Biphasic, Trabert, Faradics, drainage current
Mid frequency: Outputs: 2 Frequency: 2,5 KHz to 20 KHz ,IF bipolar, IF quadripolar, IF isoplanar, IF vectorial, MF of stimulation, Kotz, IF horizontal
Graphic and coloured LCD with touch-screen
Pre-set programs with pictures
Free memories
On inquiry:
HV current
Trolley with 4 boxes
1 cm2 1-3 MHz head
1 MHz 8 cm large head with strap for static and underwater treatments
connector combining electrotherapy to ultrasound applications
Compact dimensions along with the wide versatility of the combined
2846703
Request information / offer for products
2844743